AC supply voltage class |
380 / 400 V |
|
Mounting type |
Screw-mounted mounting plate |
|
Mounting position |
Free convection; vertical mounting preferred |
|
Product weight |
2100 g |
|
Display |
LED: green / yellow / red |
|
Control elements |
Optional: CDSB control unit |
|
Complies with standard |
EN61800-3 EN61800-5-1 EN61800-5-2 EN ISO 13849-1 |
|
Based on standards |
EN50581 EN 60204-1 EN 61508-1 EN61508-2 EN61508-3 EN61508-4 EN61508-5 EN61508-6 EN61508-7 EN61800-2 EN62061 |
|
Resolution |
RCM mark c UL us — Listed (OL) |
|
KC marking |
KC-EMV |
|
CE marking (see declaration of conformity) |
According to the EU EMC Directive according to the EU Machinery Directive according to the EU RoHS Directive |
|
UKCA marking (see declaration of conformity) |
According to UK EMC regulations according to UK machinery regulations according to UK RoHS regulations |
|
Certification body |
TÜV Rheinland UK Ltd. 01/205U/5640.01/23 TÜV Rheinland 01/205/5640.01/23 UL E331130 |
|
Storage temperature |
-25 °C ... 55 °C |
|
Ambient temperature |
0 °C ... 50 °C |
|
Note on ambient temperature |
At ambient temperatures above 40 °C, derate power by 3% for each 1 °C. |
|
UL ambient temperature |
0 °C ... 50 °C |
|
Relative humidity |
5–90%, non-condensing |
|
Maximum altitude |
2000 m |
|
Note on maximum installation altitude |
From 1000 m, power derating of 1% per 100 m. |
|
Degree of protection |
IP20 |
|
Overvoltage category |
III |
|
Pollution degree |
2 |
|
Surge voltage resistance |
6 kV |
|
Material information |
RoHS compliant |
|
LABS conformity |
VDMA 24364, zone III |
|
Rated phase operating voltage |
3-phase |
|
Rated AC operating voltage |
400 V |
|
AC input voltage range |
200 V ... 480 V |
|
Mains frequency |
48 Hz ... 62 Hz |
|
Rated load supply current |
3 A |
|
Peak current, load supply |
9 A |
|
Active PFC |
No |
|
Mains filter |
Integrated |
|
System voltage according to EN 61800-5-1 |
300 V |
|
Maximum rated mains short-circuit current |
10 kA |
|
Mains types |
TN IT |
|
Rated DC supply voltage |
560 V |
|
Permissible load current range |
± 10 % |
|
Maximum DC link voltage |
800 V |
|
Integrated braking resistor |
130 Ω |
|
Pulse power of braking resistor |
5 kVA |
|
Pulse braking resistor |
850 Ws |
|
Rated braking resistor power (IEC) |
48 W |
|
External braking resistor |
130 Ω ... 250 Ω |
|
Maximum continuous power of external braking resistor (IEC) |
600 W |
|
Rated voltage, DC logic supply |
24 V |
|
Permissible logic voltage range |
± 20 % |
|
Current consumption for logic supply without holding brake |
0.5 A |
|
Current consumption for logic supply with holding brake |
1.5 A |
|
Maximum power consumption of logic unit with holding brake and I/O |
2 A |
|
AC output voltage range |
3× (0 to input voltage), V |
|
Rated current per phase, RMS |
2.5 A |
|
Peak current per phase, RMS |
7.5 A |
|
Maximum duration of peak current |
2 s |
|
Rated controller power |
1200 VA |
|
Maximum performance |
3600 VA |
|
Output frequency |
0 Hz ... 599 Hz |
|
Maximum motor cable length without additional mains filter |
50 m |
|
Maximum holding brake output current |
1 A |
|
Maximum voltage drop from logic supply to brake output |
0.8 V |
|
Number of inputs for motor temperature sensors |
1 |
|
Controller operating mode |
Cascaded control; P position controller; PI speed controller; PI current controller for F or M; profile mode with record and direct modes; interpolation via fieldbus; synchronous operating modes; homing; setup mode; automatic tuning… |
|
Operating mode |
Field-oriented control; position resolution 24 bit/rev; sampling frequency 16 kHz; PWM at 8 or 16 kHz; 3rd-harmonic vector modulation; real-time data acquisition; 2 capture inputs (x, v, F); 2 output triggers (x, v, F); 2 position sensor inputs… |
|
Ethernet interface, function |
Parameterization and commissioning |
|
Ethernet interface, protocol |
TCP/IP |
|
Fieldbus interface, protocol |
EtherCAT EtherNet/IP Modbus/TCP PROFINET IRT PROFINET RT |
|
Fieldbus interface, function |
Bus connector: EtherCAT slave; PROFINET slave; EtherNet/IP slave |
|
Fieldbus connection |
EtherCAT EtherNet/IP Modbus/TCP PROFINET |
|
Communication profile |
CiA402; CoE (CANopen over EtherCAT); EoE (Ethernet over EtherCAT); FoE (file over EtherCAT); PROFIdrive; DriveProfile |
|
Inter-process interface |
AC1: variable-speed drives; AC3: drive with positioning; AC4: synchronous servo drive; drives with speed control and positioning; I/O mode for 256 positioning records; interpolated CSP mode; interpolated m… |
|
Fieldbus interface, data transmission rate |
100 Mbps |
|
Fieldbus interface, connection type |
2 sockets |
|
Fieldbus interface, connection technology |
RJ45 |
|
Encoder interface, function |
BiSS-C; EnDat 2.1 encoder; EnDat 2.2 encoder; Hiperface; incremental encoder; Nikon encoder; SIN/COS encoder |
|
Encoder interface 2, function |
Incremental sensor; SIN/COS encoder |
|
Synchronization interface, function |
A/B/Z encoder emulation; A/B/Z encoder input |
|
Encoder interface output, characteristics |
Maximum output frequency 1 MHz; max. 16384 pulses/rev |
|
Encoder interface input, characteristics |
Maximum output frequency 1 MHz; max. 16384 pulses/rev |
|
Number of digital logic inputs |
12 |
|
Logic input switching |
PNP (positive switching) |
|
Logic input characteristics |
In some cases freely configurable; certain safety functions; not galvanically isolated |
|
Logic input specification |
According to IEC 61131-2, type 3 |
|
Logic input operating range |
-3 V ... 30 V |
|
Number of high-speed logic inputs |
2 |
|
Time resolution of high-speed logic inputs |
1 ms |
|
Number of 24 V DC digital logic outputs |
6 |
|
Output switching logic |
PNP (positive switching) |
|
Digital logic output characteristics |
In some cases freely configurable; not galvanically isolated; several diagnostic outputs |
|
Maximum digital logic output current |
20 mA |
|
Number of high-speed switching outputs |
2 |
|
Time resolution of high-speed switching outputs |
1 ms |
|
Number of potential-free switching outputs |
1 |
|
Maximum current of potential-free switching outputs |
50 mA |
|
Number of analog setpoint inputs |
1 |
|
Input value characteristics |
Differential inputs; configurable for speed or current/force |
|
Setpoint input operating range |
± 10 V |
|
Analog input operating range |
±10V |
|
Setpoint input impedance |
70 kΩ |
|
Safety function |
Safe brake control (SBC); safe torque off (STO); safe stop 1 (SS1) |
|
Safety Integrity Level (SIL) |
Safe brake control (SBC) / SIL 3 / SILCL 3; safe torque off (STO) / SIL 3 / SILCL 3 |
|
Performance Level (PL) |
Safe brake control (SBC) / category 3, performance level e; safe torque off (STO) / category 4, performance level e |
|
Diagnostic coverage |
97 % |
|
Safe Failure Fraction (SFF) |
99 % |
|
Hardware fault tolerance |
1 |
|
Number of safe 2-channel inputs |
2 |
|
Number of diagnostic outputs |
2 |