Quantity
|
Price
|
||
|
|
|||
|
|
|||
LX3V BD boards for compact WECON PLC expansion
WECON LX3V BD boards fit a compatible slot in the controller, adding channels or interfaces without a separate external module. This category includes boards for analog signals, temperature sensors and industrial communications. They are useful when the PLC needs additional functions while the control cabinet layout must remain compact.
Boards in this category
- Analog inputs: versions for current or voltage signals, including two-channel and four-channel boards. Check the required range for each sensor.
- Analog outputs: boards for sending setpoints to actuators, plus combined input and output versions.
- Temperature measurement: boards for PT100 sensors and thermocouples. Match the input type to the sensor.
- Communications: an RS485 board and an Ethernet board for the appropriate compatible controllers. An available slot alone does not confirm support for a particular communications board.
Check compatibility before ordering
Confirm the PLC's exact part number, firmware version and available BD slots. For an analog board, also check channel count, signal type and range. Some LX3V BD boards can be used with LX5 controllers, but the LX3V-2RS485-BD and LX3VP-ETH-BD communications boards are exceptions. Check the supported controller version separately when selecting an Ethernet board.
Related categories
Find a controller among compact WECON PLCs. For external expansion, explore LX3V expansion modules. Other compact boards are listed under LX5V BD modules. See the full WECON PLC and module range.
Need help choosing a BD board?
Send us the PLC part number, signal type and channel count. An engineer can help select a board and check compatibility.
Request a selectionFAQ: WECON LX3V BD boards
How is a BD board different from an external module?
A BD board fits a compatible slot in the PLC. An external module connects through a separate expansion interface. Check the controller's support for either option.
How many BD boards can I install?
The number of available slots depends on the PLC model and version. Check the documentation for the controller's exact part number.
Can I use an LX3V BD board with an LX5 controller?
Some boards are compatible with LX5 PLCs. The LX3V-2RS485-BD and LX3VP-ETH-BD communications boards are exceptions; check the specific PLC and board combination.
Can I add Ethernet to any LX3V PLC?
No. The LX3VP-ETH-BD board requires a compatible controller version and supported firmware.
What information is needed for selection?
Provide the PLC part number and version, required function, channel count, signal type and range, and any boards already installed.