Quantity
|
Price
|
||
|
|
|||
|
|
|||
Flow sensor SFAH-5U-G18FS-PNLK-PNVBA-M8
SKU
8158425
In stock
Specifications
| Product series | SFAH |
|---|---|
| Switching output | 2 x PNP or 2 x NPN, switchable |
| Symbol | 00995794 |
| Resolution |
RCM mark c UL us - Listed (OL) |
| CE marking (see declaration of conformity) |
In accordance with EU EMC Directive In accordance with EU RoHS Directive |
| UKCA marking (see declaration of conformity) |
In accordance with UK EMC regulations In accordance with UK RoHS regulations |
| Certification body | UL E322346 |
| Material information | RoHS compliant |
| Measured variable | Mass flow Volumetric flow rate |
| Measurement principles | Thermal |
| Measurement method | Heat transfer |
| Operating medium | Compressed air according to ISO 8573-1:2010 [6:4:4] Nitrogen |
| Medium temperature | 0 °C ... 50 °C |
| Ambient temperature | 0 °C ... 50 °C |
| Minimum load resistance, output voltage | 20 kΩ |
| Short-circuit protection | Yes |
| DC operating voltage range | 22 V ... 26 V |
| No-load current | ≤25 mA |
| Reverse polarity protection | For all electrical connections |
| Mounting type | Using accessories |
| Mounting position | Any |
| Pneumatic connection | Female thread G1/8 |
| Product weight | 90 g |
| Housing material | PA-reinforced |
| Degree of protection | IP40 | III |
| Corrosion resistance class (CRC) | 2 - moderate corrosion stress |
| LABS conformity | VDMA24364-B2-L |
| Electrical connection 1, connection type | Connector |
| Electrical connection 1, connection technology | M8x1 A-coded according to EN 61076-2-104 |
| Electrical connection 1, number of contacts/cores | 4 |
| Electrical connection 1, mounting type | Non-rotatable |
| Electrical connection 1, connection diagram | 00991171 |
| Electrical connection 1, universal mounting type |
Compatible with locking mechanism Compatible with rotating screw lock |
| Materials in contact with medium | Silicon Silicon nitride High-alloy stainless steel |
| Switching function | Window comparator Threshold comparator Automatic difference monitoring |
| Switching element function | NC/NO (normally closed/normally open contact, switchable) |
| Maximum output current | 100 mA |
| Protocol | IO-Link |
| IO-Link, protocol version | Device V 1.1 |
| IO-Link, profile | Smart Sensor Profile |
| IO-Link, functional classes | Binary data channel (BDC) Process data variable (PDV) ID Diagnostics Teach channel |
| IO-Link, communication mode | COM2 (38,4 kBaud) |
| IO-Link, SIO mode support | Yes |
| IO-Link, port class | A |
| IO-Link, process data width IN | 3 Byte |
| IO-Link, process data content IN | 1 bit BDC (monitoring volume) 14 bit PDV (measurement flow) 2 bit BDC (monitoring flow) |
| IO-Link, service data content IN | 32-bit volume/mass reading |
| IO-Link, minimum cycle time | 4 ms |
| IO-Link, data storage required | <500 bytes |
| Display type | Multicolour LCD |
| Display units | g g/min l l/h l/min scft scft/year scft/min |
| Setting parameters | IO-Link Teach-In using display and buttons |
| Pollution degree | 3 |
| Manipulation protection | IO-Link PIN code |
| Maximum current load resistance | 500 Ω |
| Overload resistance | Available |
| Operating pressure | -0.9 bar ... 10 bar |
| Flow direction | Unidirectional |
| Flow measuring range, initial value | 0.1 l/min |
| Flow measuring range, final value | 5 l/min |
| Nominal temperature | 23 °C |
| Flow value accuracy | ± (2% o.m.v. + 1% FS) |
| Temperature coefficient range in ± %FS/K | Typ. 0.15% FS/K |
| Analog output | 0 - 10 V 4-20 mA 1 - 5 V |
| Flow characteristic initial value | 0 l/min |
| Flow characteristic final value | 5 l/min |
| Zero-point repeatability in ± % FS | 0.2 %FS |
| Repeatability range in ± %FS | 0.8 %FS |
| Pressure influence range in ± % FS/bar | 1 %FS/bar |
| Pneumatic connection, output direction | Straight |
| Pressure drop | <5 mbar |
| Cleanroom suitability measured according to ISO 14644-14 | Class 4 according to ISO 14644-1 |
Share on social media
Share
Share
Share